Rotary glide path system

TransformSTM MicroPath

Third-party names identify file systems and workflow compatibility only. No affiliation, sponsorship or endorsement is implied. Trademark notice.

Premium Performance. Single-Use. Exceptional Value.

Protocol card Explore Hybrid Micropath Negotiating Techniques in Calcified Canal Systems
MP
TransformS™ MicroPath rotary glide path files

Compatible with all glide path files

MicroPath sequence

Three precise guide path sizes

Progressive preparation from #13 through #17.

Advanced manufacturing technology

TransformS MicroPath #13 guide path file with purple identification
#13
TransformS MicroPath #15 guide path file with white identification
#15
TransformS MicroPath #17 guide path file with yellow identification
#17

Product film

MicroPath, in motion.

57-second product film TransformS™ MicroPath

Interactive anatomy

Explore the upper first molar in 3D

Open larger viewer ↗

Three danger points—and why MicroPath matters

Scroll to read all three danger points ↕

Danger point one: the first bend

Finding MB2 is only the beginning. Beyond the pulp chamber, the canal may curve abruptly. A hand file can enter, then stop, but resistance does not always mean the canal is blocked.

A stiff stainless-steel file may press into the dentine instead of following the curve. Forcing it risks creating a ledge that makes further negotiation difficult. Moving from size ten to size fifteen increases tip diameter by fifty percent and reduces flexibility.

Use small, appropriately pre-curved hand files for exploration. Respect the length they can negotiate without force, and reassess if progress stops.

The seventeen-millimetre MicroPath MB2 file is designed for this first danger point. Its nickel-titanium Flex-Ion construction provides flexibility for abrupt curves within the first three to five millimetres. Its short format creates handpiece headroom, while the size fifteen tip and point-zero-five taper provide an initial preparation step. The aim is controlled entry along the anatomy without creating a ledge.

Danger point two: the deeper curve

Passing the first bend does not mean the canal is straight. Deeper in the root, it may change direction again where the mesio-buccal one and mesio-buccal two canals meet. A hand file may pass the first curve but meet resistance here. Continued pressure can create a second ledge, sometimes obscured on a bite-wing radiograph.

MicroPath size thirteen and fifteen glide-path files are designed for this deeper pathway. Both have a point-zero-three taper. Size thirteen provides an intermediate step between ten and fifteen; size fifteen develops the glide path further when anatomy permits. Their smaller taper limits the increase in diameter along the working portion.

This creates a controlled transition to a reproducible glide path before larger shaping files are introduced. These files support careful exploration; they do not replace it. Let anatomy and tactile feedback guide each step.

Danger point three: instrument stress

At a deeper curve, a rotating instrument undergoes repeated tension and compression. Cyclic fatigue may cause separation, leaving a fragment toward the apex. Binding can also create torsional overload.

MicroPath establishes the glide path before larger shaping files encounter this anatomy. The short MB2 file manages initial access, followed by a size thirteen or fifteen glide-path file as appropriate. Each instrument has a defined role, rather than forcing one file through every stage. Flex-Ion technology is designed to add safety in this demanding zone.

A University of Pennsylvania study by Iqbal, Kohli and Kim recorded eighty-one separated instruments in four thousand eight hundred and sixty-five endodontic cases. Almost eighty-three percent occurred in the apical third.

MicroPath supports a safer sequence: establish entry, develop a confirmed glide path, then shape while respecting the curvature.

Upper first molar with translucent exterior, red canals and a MicroPath file following MB2; its handle is outside the crown.

Rotate · zoom · isolate canals · inspect apical branches

MB2 glide path: the thicker rotating file follows the approved route to its apical endpoint, with the single 21 mm CAD stopper seated at the top cusp reference. Non-to-scale educational animation; wall contact/overlap is permitted, not simulated as cutting or a clinical file-fit measurement.

Watch video instead

File-system protocol

Downloads

All protocol cards & complete collection →

TransformS™ MicroPath protocol card

PDF · 2 pages · Glide-path sequence and motor settings.

Download PDF

USA product range

Part numbers

Swipe left to view part numbers

File Length Pack Part number
13/.03 21 mm 6 TSMP-130321RF
13/.03 25 mm 6 TSMP-130325RF
13/.03 29 mm 6 TSMP-130329RF
15/.03 21 mm 6 TSMP-150321RF
15/.03 25 mm 6 TSMP-150325RF
15/.03 29 mm 6 TSMP-150329RF
17/.03 21 mm 6 TSMP-170321RF
17/.03 25 mm 6 TSMP-170325RF
17/.03 29 mm 6 TSMP-170329RF
20/.03 21 mm 6 TSMP-200321RF
20/.03 25 mm 6 TSMP-200325RF
20/.03 29 mm 6 TSMP-200329RF
25/.03 21 mm 6 TSMP-250321RF
25/.03 25 mm 6 TSMP-250325RF
25/.03 29 mm 6 TSMP-250329RF
15/.05 17 mm 6 TSMP-150517RF

Part numbers reflect the current EndoTech USA product register. Product availability, approved labeling, and IFU documentation govern.