Education/ET constant-taper protocol

TransformSTM ET

Establish the glide path, then select .04 or .06 taper. Follow the illustrated ET route below and choose the preparation that fits the canal.

Compatible with X7 and HyFlex

Third-party names identify file systems and workflow compatibility only. No affiliation, sponsorship or endorsement is implied. Trademark notice.

Illustrated sequence / protocol card page 3

Glide → open → prepare

15/.03 → 20/.06 → 17/.04 → 25/.04

  1. MicroPath 15/.03 glide-path file with one white identification band and a white stopper

    MicroPath 15/.03

    Glide path

    To length
  2. ET 20/.06 file with yellow identification band and yellow stopper

    ET 20/.06

    Open / preflare

    To midroot
  3. ET 17/.04 file with yellow upper band, silver gap, white lower band and white stopper

    ET 17/.04

    Initial preparation

    To length
  4. ET 25/.04 file with red identification band and red stopper

    ET 25/.04

    Final preparation

    To length

Keep preflare controlled. Use 20/.06 toward mid-root only within an established, sufficiently wide straight coronal path. Stop before curvature or resistance; mid-root is not a mandatory depth.

Sequence + clinical decisions

Step by step

Choose the route that fits the canal.

Entry check

Assess anatomy, isolate with a rubber dam, scout with a small hand file and establish working length (WL).

  1. 01

    Glide path

    After hand scouting, select MicroPath 15/.03 or 17/.03 for routine glide preparation; use 13/.03 for complex or narrow paths. Confirm a smooth, reproducible path to working length.

  2. 02

    Open the entrance

    Use the dedicated 17/.08, 17 mm opener only in the established coronal path. Brush away from the furcation and stop before curvature or resistance. The illustrated 20/.06 preflare is an optional route for a confirmed, sufficiently wide straight coronal path.

  3. 03

    Initial preparation · 17/.04

    Follow the glide path with light pressure, withdrawing frequently to clean and inspect. Reconfirm working length after coronal enlargement.

  4. 04

    Develop the shape · 25/.04

    Try 25/.04 passively to working length. If it cannot advance, use 20/.04, then return to 25/.04. Never drive through resistance.

  5. 05

    Choose the endpoint

    Select further enlargement from the apical assessment and anatomy. Use 25/.06 or larger .04/.06 files only when justified.

  6. 06

    Complete treatment

    Record final size, taper and working length. Complete disinfection, check the selected cone at working length, then obturate under length control.

Optional 20/.06 preflare

A size 20/.06 file taken toward mid-root before 17/.04 and 25/.04 can improve cone fit in the final preparation. Use it only within the confirmed straight coronal path and verify the final cone at WL.

Alternative crown down

ET files can also be used in a crown-down technique: 25 → 20 → 17, in .04 or .06 taper.

A dedicated instrument

Orifice opener

The orifice opener is a unique 17/.08, 17 mm file. It was created for clinicians who find larger-tipped orifice shapers difficult to enter into smaller calcified orifices, helping position the instrument when redefining a difficult canal entrance.

Use it only in the established coronal path. Brush away from the furcation and stop before curvature or resistance.

Dedicated 17/.08, 17 mm ET orifice opener with a silver handle without a color band, pale yellow stopper and gold working section
17/.08 · 17 mmOrifice opener

Motor setup

EndoTech settings

Rotary motion · torque in N·cm

Settings printed on the approved ET protocol card.
InstrumentSpeedTorque
ET shaping files400–500 rpm2 N·cm
Orifice opener · 17/.08 · 17 mm400–500 rpm2 N·cm
MicroPath 15/.03 and 17/.03400–500 rpm2 N·cm
MicroPath 13/.03400–500 rpm1 N·cm

Read the instrument designation on the packaging before use. ET shaping files are available in sizes 15 to 45. Use EndoTech settings and the current instructions for the instrument in use.

Inspect between instruments

Keep the pathway reproducible

  • Withdraw, clean and inspect the flutes between instruments.
  • Irrigate, recapitulate with a small hand file and re-irrigate.
  • Confirm a smooth return to working length. Rebuild the path if it is no longer reproducible.
  • Record final size, taper and working length; verify the final cone at working length before obturation.

Keep the sequence to hand

ET protocol card

The three-page card includes the clinical sequence, technique notes and illustrated four-file pathway.

Adapted from the approved EndoTech card, Edition 09, 8 October 2026. The PDF retains its NZ branding. Instrument illustrations are not a dimensional scale.